Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0724-04075
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/13/2024 | Site Engineering | NOT REQUIRED | |||
08/13/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/08/2024 | Historic | REQUIRES RESUBMIT | Property is listed as a contributor to the Armory Park HPZ and requires review and approval. Please provide all items noted under Full Review in the Historic & Special Districts Application Instructions (https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf). Once the submittal is complete, please submit it under the Historic Sub-Record. Also, clarify the work the window G which appears to be converting from a door to a window. Also, clarify if the WH will be enclosed. Questions? Jodie.Brown@tucsonaz.gov |
||
07/16/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0724-04075 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with the updated construction plan set. Provide construction documents with sufficient clarity to indicate the location, nature and extent of the work proposed. PLANS: 1. Remove “Preliminary Not For Construction” from all sheets, R310. 2. The proposed window F at the laundry room may be sited within the 3’ fire separation distance from a property line. Show compliance with R302.1 (City of Tucson Amended) by providing a wall with one-hour rated materials prescribed in IBC Table 721.1(2), Items 15-1.1 to 16-1.3, R106.1 if the wall is closer than 3 feet to the property line. Show the separation distance on sheet A1.2. SECTIONS - DETAILS: 1. Provide plans detailing the extent of porch enclosure restoration shown at the Project Description, sheet G1.1. MECHANICAL PLANS: 1. Provide plans showing the location of the relocated mini split shown at keynote #1, sheet A1.1. ELECTRICAL PLANS: 1. Provide plans detailing the extent of updates listed at keynote #2, sheet G1.1. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Provide code compliant windows, N1101. Windows require a solar heat gain of 0.25 or better. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
08/07/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0724-04075 720 South 3rd Avenue – HR-3 Porch renovation (1st Review) TRANSMITTAL DATE: August 7, 2024 The site is in the HR-3 zone (UDC 4.7.12). A single-family residence is a permitted use in the R-3 zone, subject to use-specific standard 4.9.7.B.6. 1. The site is in the Armory Park Historic Preservation Zone. Design review in accordance with UDC 5.8.8 is required for the proposed exterior improvements. The Historic and Special Districts Application instructions can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf. The design review process shall be applied for as a sub-record of TC-RES-0724-04075. Zoning cannot approve TC-RES-0724-04075 until the design review process has been approved and completed. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
07/12/2024 | PDSD Application Completeness | REVIEW COMPLETED |