Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0724-04072
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/15/2024 | Residential Building | APPROVED | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Provide structural design, calculations and drawings prepared by an Arizona licensed design professional for the elevator project for both vertical and lateral resistance to loads; to include, foundation, new foundation attachment to existing foundation, elevator equipment attachment, connections, lintels, etc. IBC 107.2.1 2. Please amend plans to provide the elevator equipment installation sheets in the plan set. IBC 107.2 3. Please amend plans to indicate the private residence elevator will comply with ASME A17.1/CSA B44. IBC 107.2.1 4. Please amend plans to indicate elevator to be inspected by Industrial Commission of Arizona. IBC 107.2.1 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
08/13/2024 | Site Engineering | NOT REQUIRED | |||
08/15/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/12/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0724-04072 219 S AVENIDA DEL PALO FIERRO – PAD-10 New elevator (1st Review) TRANSMITTAL DATE: August 12, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in PAD-10 (UDC 4.7.24). A single family residence is a permitted use in the PAD. 1. Per PAD-10 page 42 approval from the Mercado District Design Review Committee is required prior to approval of this permit. Provide building plans that are stamped by the committee with your next submittal. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
07/12/2024 | PDSD Application Completeness | REVIEW COMPLETED |