Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0724-04066
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/13/2024 | Site Engineering | NOT REQUIRED | |||
| 08/13/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/18/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0724-04066 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with the updated construction plan set. SITE PLAN: 1. Show the location of the electrical service panel, R106.1.1. FLOOR PLAN: 1. Provide a floor plan showing the window size with type identified as XO or SH. A bedroom requires code compliance for egress, R310. 2. Notate if the opening between the dwelling and proposed bedroom is existing or new which requires a header consistent with Table 502.5(1). SECTIONS - DETAILS: 1. Provide a complete cross-section detail showing a foundation and pressure treated sill anchored with ½” x 10” bolts. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5. 2. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. PLUMBING PLANS: 1. Provide complete plumbing plans showing a 3” drain extended to an appropriate location, Table P3005.4.1. ELECTRICAL PLANS: 1. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 08/07/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Ramiro Olivarez Zoning Review Section PROJECT: TC-RES-0724-04066 5843 E CALLE AURORA TUCSON, AZ 85711 – R-1 Zoning Enclose Carport into Bedroom Suite (1st Review) TRANSMITTAL DATE: 08/07/2024 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9 COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. The site plan should be designed to include the information as noted on the sample plot plan. See the link below for the information that is required on the plot plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf . 1. Comment: Draw, label, and dimension the perimeter yard setbacks from all property lines to the proposed project. See the sample plot plan above for an example. 2. Comment: Label on the site plan the zone (R-1) and all the adjacent property zones (R-1). See the sample plot plan above for an example. 3. Comment: Provide the total lot coverage calculations. Per UDC article 6.4.3 lot coverage shall need to include the area of a lot covered by buildings, storage areas, including dimensioned vehicular use areas. See the sample plot plan above for an example. 4. Comment: Indicate on the site plan that the existing patio is not covered. 5. Comment: A full floor plan shall be included for the next review and label each room. (Need to verify the number of total bedrooms in the existing dwelling) 6. Comment: Draw, label, and dimension the back of curb to property line and center line of E Calle Aurora to the property line as depicted on the sample plot plan. Label and dimension the alley. See the sample plot plan above for an example. 7. Comment: Provide an elevation sheet and draw, label, and dimension the building and wall heights per UDC 6.4.4. (The wall height should be measured from design grade (from ground to tallest point).) 8. Comment: Additional comments may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Provide updated site & floor plan in the next submittal. If you have any questions about this transmittal, please contact Ramiro Olivarez Ramiro.Olivarez@tucsonaz.gov |
||
| 07/12/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |