Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0724-03974
Parcel: 138050330

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0724-03974
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/09/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/09/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT PDSD Residential Review Section

PROJECT: TC-RES-0724-03974
Connect new gas line for furnace, water heater, range, and clothes dryer-(1st Review)
(733 W Santa Paula St)

TRANSMITTAL DATE: July 9th, 2024

COMMENTS:
Plan review for the above referenced structure has been completed.

1. Label all gas appliances with gas pipe sizes. Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) (Polyethylene Plastic Pipe). Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1.

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/sample_gas_template_0.pdf

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf

Any questions please email building_official@tucsonaz.gov
07/09/2024 PDSD Application Completeness Express REVIEW COMPLETED