Review Status: Requires Resubmit
Review Details: RESIDENTIAL FENCE/WALL v.1
Permit Number - TC-RES-0724-03972
Review Name: RESIDENTIAL FENCE/WALL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/09/2024 | Residential Building | NOT REQUIRED | |||
07/30/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
07/30/2024 | Site Engineering | REQUIRES RESUBMIT | 1. Provide a side profile with footing specs for the wall. Mike Ortiz michael.ortiz@tucsonaz.gov |
||
07/22/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0724-03972 2340 E 8TH ST. – R-1 Site Wall (1st Review) TRANSMITTAL DATE: July 22, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. 1. Per UDC Article 6.6.2.I The maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard .) 1. At least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron; 2. Part of, or located on top of, a retaining wall no higher than ten feet measured from design grade and no higher than six feet measured from the top of the retaining portion of the wall; 3. A greater height is required through the rezoning process or the special exception land use process; 4. A greater height is required by a specific UDC standard. It does not appear that the proposed 7’-0” high wall called out under keynote 2 meets any of the 4 exceptions. Either the wall needs to be lowered to 6’-0” or a Design Development Options (DDO) for wall height will need to be submitted and approved prior to approval of this plan. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
07/09/2024 | PDSD Application Completeness | REVIEW COMPLETED |