Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/19/2024 | Site Engineering | NOT REQUIRED | |||
08/19/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
07/24/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0724-03926 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Provide a response letter on separate file with submitting the updated construction plan set. GENERAL COMMENTS : 1. All plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009 require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549. Show a minimum 300 SF clear solar-ready zone on a roof or framing plan, T103.3. 2. All plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. Include two clothes washer standpipes, one with gray drain-line discharge; also provide gray drain-line discharge of all second story bathing fixtures through an exterior-wall drop for future gravity distribution. Include an aliened purple colored 2” or 3” vertical drop to a cleanout cap 2’ above grade. Or notate “Gray water provision not required when property has less than 200 SF available for gray water distribution.” Appropriate details are found at the web site: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations 3. Show compliance with the Electric Vehicle Supply Equipment Ordinance adopted by the City of Tucson Ordinance #11844 on 6/22/2021. Include a 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle for charging an electric vehicle at a proposed parking space. 4. A special inspection request is required with the updated plans for the post-tensioned slab, R109.2. Provide a certified inspector seal on the form found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Inspections MECHANICAL PLANS: 1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Show the minimum airflow rate setting and location of the device requiring this adjustable setting. A two- or three-bedroom dwelling greater than 1500 SF requires a 60 CFM continuous setting. Show this setting on sheet #8. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
08/16/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-0724-03926 883 W CALLE DE LOS HIGOS – PAD-10 New SFR (1st Review) TRANSMITTAL DATE: August 16, 2024 Resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in PAD-10 (UDC 4.7.24). A single-family residence is a permitted use in the PAD. 1. Per PAD-10 Parking - Neighborhood General 1. Dwelling Unit: One space on-site per dwelling unit is required. Clearly show the required parking space on site and demonstrate how access is provided. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
07/25/2024 | Fire New Construction | REVIEW COMPLETED | |||
07/18/2024 | PDSD Application Completeness | REVIEW COMPLETED |