Permit Number: TC-RES-0724-03916
Parcel: 113094600

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0724-03916
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/17/2024 Fire New Construction NOT REQUIRED
08/09/2024 Site Engineering NOT REQUIRED
08/18/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/15/2024 Residential Building REQUIRES RESUBMIT TC-RES-0724-03916
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance.

Provide a response letter on separate file with the updated construction plan set.

SITE PLAN:

1. Provide a site plan showing the electrical service line to the primary dwelling, R106.1.1. Show any required alterations.

STRUCTURAL PLANS:

1. A roof projection may not extend closer than 24” to the adjoining (neighboring) property line. Any part of a roof projection extending into the 3-foot fire separation distance from the property line requires not less than one-hour fire-resistive construction on the underside, IBC Table 721.1(2). Show a means of compliance, R302.1 (City of Tucson Amended).

ELECTRICAL PLANS:

1. An overhead service conductor over the proposed building requires an 8-foot clearance above the proposed roof, E3604.2.1.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
07/31/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0724-03916
1043 East Alta Vista Street – R-2
Office and porch addition (1st Review)

TRANSMITTAL DATE: July 31, 2024

The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1) or a Board of Adjustment variance (UDC 3.10.3).

1. Remove the porches from the lot coverage calculation, as roofed areas, open on at least one side, which provide shelter to exterior areas, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking, are not included in the lot coverage calculation (UDC 6.4.3.C.1.a).

2. According to the Pima County Assessor’s Office, the lot size of the property is 6,930 square feet. Revise the lot coverage calculations to reflect the correct lot size.

3. Per Tucson Unified Development Code (UDC) Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required perimeter yard is six feet or 2/3 the height of the exterior building wall, whichever is greater. Based on a wall height under 9’-0”, the required side perimeter yard is 6’-0” as measured from the west lot line to the proposed sleeping quarters addition. The proposed side perimeter yard is 3’-5”.

There are three mechanisms to reduce the required side perimeter yard. A neighbor’s setback waiver process in accordance with UDC 6.6.2.D may be utilized to reduce the side perimeter yard. The waiver shall be pasted directly onto the site plan and signed by the owners of 1037 East Alta Vista Street with the following language:

My name is ________ and I am the owner of property located at ________. I have reviewed the site plan and have no objection to the structure being constructed __ feet from the property line as depicted on the site plan.

Signature: ________

Date: _________

If the required neighbor setback waivers cannot be obtained, a Design Development Option (DDO) in accordance with UDC 3.11.1 may be utilized to reduce the side perimeter yard. A Board of Adjustment variance can also be utilized to reduce the side perimeter yard depending on how the following comments are addressed.

4. The existing detached carport appears in aerial photography in 2021. A zoning compliance review was not obtained for the structure. Provide the applicable setbacks and wall heights of the existing carport.

As the existing carport appears to have been constructed at the south and east lot lines, a Board of Adjustment variance is required to be granted to allow the carport to remain with front street and side perimeter yards of 0’-0”.

5. Ensure the square footage of the existing residence and of the existing sleeping quarters are provided separately. Per UDC 6.6.3.E, the total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement. A Board of Adjustment variance is required to exceed this requirement.

The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. Contact Georgia.Pennington@tucsonaz.gov or Mark.Castro@tucsonaz.gov if you have questions about the DDO process.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.
07/10/2024 PDSD Application Completeness Express REVIEW COMPLETED
08/18/2024 Site Landscape REVIEW COMPLETED