Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.5
Permit Number - TC-RES-0724-03914
Review Name: RESIDENTIAL NEW DWELLING v.5
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/20/2024 | Site Zoning | APPROVED | |||
| 12/20/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/04/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0724-03914 2nd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Provide a response letter on separate file with the updated construction plan set. Separate the response letter from the construction plan set. GENERAL COMMENTS : 1. All plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. The ordinance revision now requires a gray drain line discharge from one fixture for a one-story dwelling. Show a second clothes washer standpipe plumbed to an exterior wall above grade when feasible. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations PLANS: 1. Provide a clear set of the manufacturer’s trusses documents in a separate file rather than on sheet #8, R106.1. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Clarify the ceiling/roof insulation detail showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing along with the batt insulation. PLUMBING PLANS: 1. Show all drainage fixtures with connection to the public sewer system, P2602.1. Update sheet #4 with a dual standpipe detail for the clothes washer. Any other fixture requires an approved diverter valve for optional gray water discharge. 2. Gray water systems may only receive waste discharge from bathtubs, showers, lavatories, clothes washers, and laundry trays, P2601.2 & Table P3009.9. Remove the gray drain lines from the food preparation sink. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
||
| 11/19/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |