Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.4
Permit Number - TC-RES-0723-06855
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/29/2024 | Residential Building | APPROVED | |||
| 05/14/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/14/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0723-06855 3520 North Flowing Wells Road – O-3 New single-family residence (3rd Review) TRANSMITTAL DATE: May 14, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). 1. Remove the “existing covered porches” from the lot coverage calculation as roofed areas, open on at least one side, which provide shelter to exterior areas, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking, are excluded from the lot coverage calculation (UDC 6.4.3.C.1.a). 2. The zoning classification of the property and of surrounding properties is incorrectly listed as “OC-3” and should be corrected to “O-3.” The zoning classification of the property to the east shall also be listed as “MH-1.” 3. Perimeter yards are based on a measurement from the design grade elevation to the highest point of an exterior building wall (see UDC 6.4.5-B and Figure 6.4.5-A). Per UDC Table 6.3-3.A, when a residential use is adjacent to a residential zone, the required side and rear perimeter yards are six feet or 2/3 the height of the exterior building wall, whichever is greater. Based on a wall height of 15’-0”, the required side perimeter yard is 11’-3” as measured from the south lot line. The proposed side perimeter yard is 10’-0” as measured from the south lot line. Design Development Option (DDO) approval is required to reduce the side perimeter yard from 11’-3” to 10’-0”. The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. Contact Georgia.Pennington@tucsonaz.gov if you have questions about the DDO process. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
| 04/10/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |