Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0723-06837
Parcel: 122183360

Address:
3526 E LEE ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0723-06837
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/10/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/10/2023 Residential Building REQUIRES RESUBMIT 1. Show an individual water heater for each building, P2801.1. Also, the maximum length of hot water piping shall not exceed 50’, IPC607.2.
2. Show an individual accessible water supply shut off for each dwelling unit, P2903.9.1.
3. Comply with energy values for glazing is U=0.40, ceiling R=38 (R-30 for a qualifying room addition) and walls R=13 for conditioned spaces. Show the “R” values of insulation and the maximum “U” factors of the windows and doors on the plans as well as the solar heat gain coefficient SHGC minimum value of 0.25, N1102.1.
08/03/2023 Site Engineering REQUIRES RESUBMIT This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.)
Please start a new FUP at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home
NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TI’s and solar). Construction of separate builds/new structures does not require a cost estimate to be provided.
Instructions:
1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record
2. Locations -> Confirm the location is accurate to the project. Click “Next”
3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next”
4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next”
5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next”
6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next”
7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next”
8. Review and Submit -> Review all information to ensure accuracy. Click “Submit”
Contact Lianne Evans at lianne.evans@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP.
08/07/2023 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Nathan Herrera
Planner

PROJECT: TC-RES-0723-06837
Address: 3526 E Lee St. Tucson, AZ. 85716
Parcel: 122-18-3360
Zoning: R-2
Existing Use: Single Family Residence
Project Description: Detached Accessory Structure- Workshop

TRANSMITTAL DATE: 8/07/2023

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.


1. COMMENT: Clarify if the “workshop” is existing. Aerials show an existing structure on the property that appears to be in the same location of the proposes workshop/studio.

If existing structure is to be demolished have a call out on the site plan stating so. If not, clearly identify which part of the proposed structure is existing and which part will be the addition.

2. COMMENT: Aerials show unpermitted structures on the property. It appears that at some point after 2005 a front and rear porch were added to the property. The rear porch is not shown on the site plan. Add to the site plan.

3. COMMENT: There appears to be an unpermitted structure connected to the rear of the existing storage shed in the rear of the property that encroaches into the required property setbacks. Show the porch on the site plan and provide a dimension showing the setback from the property, or state if it is to be demolished.

4. COMMENT: Aerials show multiple shade structures on the property that do not have a permit history. Add the shade structures to the site plan, and provide a dimension showing the setback from the property line so zoning can confirm they meet required setbacks.

5. COMMENT: Zoning cannot approve of this permit until the unpermitted structures are brought into compliance, or are removed.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised residential building permit along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@TucsonAZ.gov or at 520-837-4894
08/02/2023 PDSD Application Completeness Express REVIEW COMPLETED