Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.4
Permit Number - TC-RES-0723-06821
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/08/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/15/2024 | Residential Building | REQUIRES RESUBMIT | PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with the updated construction plan set. Provide a plan set of all sheets including S-1 and S-2. Provide the sealed engineering report and any other supporting documents for a complete permit submittal. Revise the site plan showing height of retainer, height of wall on top and length of each segment of structure. Keynote #1 states a 5 foot wall on top but the plan shows shows a 6 foot height at these locations. Also, show the length of keynote #3. |
||
| 11/06/2024 | Site Engineering | REQUIRES RESUBMIT | See Residential Building comments RE: Sheet S2 Mike Ortiz michael.ortiz@tucsonaz.gov |
||
| 11/08/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-0723-06821 7438 E 29th Street Tucson, AZ 85710 Retainer wall with CMU wall on top (2nd Review) TRANSMITTAL DATE: 11/8/2024 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Provided plans have conflicting heights on them. Keynote #1 calls out a 3’ high retaining wall with 5’ high patio wall however the provided plans are showing a 6’ high wall for keynote #1. 2. Comment: Additional comments may be forthcoming depending on responses to comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov (520) 837-4977. |
||
| 10/09/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |