Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.2
Permit Number - TC-RES-0723-06776
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/26/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/26/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Show gas pipe sizes in compliance with connected demand, G2413.3 & Table G2413.4(1). Provide a gas line isometric or table for showing the BTU demand and length of line to each gas appliance. The developed pipe length extends from the meter to the furthest appliance. Verify that the diagram shows length to each appliance with BTU ratings shown at each branch. A range is typically 65,000 BTU total with all burners. See the sample template https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/sample_gas_template_0.pdf |
||
| 07/26/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |