Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0723-06482
Parcel: 137292000

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0723-06482
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/20/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/20/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0723-06482 (1782 W OAK RIDGE CT TUCSON, AZ 85746)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electric Code (NEC).

1. Provide a system layout plan showing the location of system components in relation to structures and utilities, R106.1.
2. Provide a 3-line diagram identifying each component and circuit notating sizes and installation details.
3. Provide and show Main Service Panel (MSP) taps in compliance with NEC 705* (NEC 705.12) 705.12(B)(2)(3) b Busbars.) 120% bus bar rule.
4. Provide the exact wording and location for the Photovoltaic system Warning signs and labels as required in NEC 690 and 705.12(B)(2)(3) b-c.
o “Photovoltaic System Disconnect” NEC 690.13(B)
o NEC 690 Part VI Markings – NEC 690.51-58
o NEC 690.33(E).

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
07/12/2023 PDSD Application Completeness Express REVIEW COMPLETED