Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0723-06474
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/14/2023 | Site Engineering | NOT REQUIRED | |||
| 07/27/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/27/2023 | Residential Building | REQUIRES RESUBMIT | Provide a complete construction plan set showing 2018 IRC compliance after DDO approval. Any structure placed in the 3-foot fire separation distance from the neighboring property line requires not less than one-hour fire-resistive construction for reducing fire spread across the property line, R302.1. Fire rated materials are found in IBC Table 721.1(2), Items 15-1.1 to 16-1.3. |
||
| 07/19/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-0723-06474 915 E. Pastime Rd. - R-2 Bedroom, front & rear porch and carport addition (1st Review) TRANSMITTAL: July 18, 2023 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1. roofed areas, open on at least one side, such as a porch are not included in the coverage. 2. Provide the scale of the plot plan. 3. Per UDC Article 6.4.5.B.2 A vertical structural member(s) (i.e., post, column, dormer wall) supporting a roof extension from the principal structure is considered a wall for applying perimeter yard requirements. That said provide a setback dimension from the post supporting the proposed front porch and carport to the street property line. 4. The setback dimension from the proposed carport to the west property line is not clear and appears to be 5’-10”. Per UDC Article 6.4.5.B.2 A vertical structural member(s) (i.e., post, column, dormer wall) supporting a roof extension from the principal structure is considered a wall for applying perimeter yard requirements. That said clearly shown the post supporting the carport and provide a readable setback dimension from the post to the west property line. Based on a wall height of 9’-0” or less and it the setback is less than 6’-0” a Design Development Option (DDO) to reduce the setback will be required. 5. Based on a wall height of 11’-0” the required perimeter yard setback from the proposed bedroom addition to the east property line is 7’-4”, proposed setback is 2’-6”, a Design Development Option (DDO) to reduce the setback will be required. 6. The dimension provided from back of curb to the front street property line is not correct. Per Construction Plan I-659B, found at, https://maps-and-records.tucsonaz.gov/construction-plans/details/I-659B, the dimension should be 12’-0”. Also provide a dimension from the center line of Pastime to the back of curb, this dimension should be 18’. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 07/25/2023 | Zoning Modifications - DDO | REQUIRES RESUBMIT | FROM: Georgia Pennington, Planner DATE: 7/25/2023 COMMENTS: 1. A clearance space of at least four feet in width must be provided between the bike rack and pillars. Please UDC Section 7.4.9 for more information on Bicycle Parking Design Criteria. If you have questions about this transmittal, please email me at georgia.pennington@tucsonaz.gov. |
||
| 07/13/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |