Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0626-03550
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/10/2026 | Residential Building - Standard | APPROVED | INCLUSIVE HOME DESIGN BATHROOM WALL REINFORCEMENT: IN ALL BATHROOMS ON THE ACCESSIBLE ROUTE, REINFORCEMENT SHALL BE INSTALLED TO ALLOW THE FUTURE INSTALLATION OF GRAB BARS ON WALLS ADJACENT TO THE TUB AND TOILET. IN ADDITION, REINFORCEMENT SHALL BE INSTALLED IN SHOWER COMPARTMENTS FOR FUTURE INSTALLATION OF GRAB BARS. THIS REINFORCEMENT SHALL BE INSTALLED FLUSH WITH THE STUDS AND AT THE FOLLOWING LOCATIONS: TOILET: 33”-36” ABOVE THE FLOOR ON ALL ADJACENT WALLS. HORIZONTAL LENGTH OF REINFORCEMENT SHALL BE SUFFICIENT TO ALLOW A 42” GRAB BAR AND 24” REAR GRAB BAR. TUB: HORIZONTAL LENGTH REINFORCEMENT SHALL BE SUFFICIENT TO ALLOW FOR; BACK WALL: TWO BACKING REINFORCEMENTS, ONE BACKING REINFORCEMENT HORIZONTAL POSITION 33” MINIMUM AND 36” MAXIMUM ABOVE THE FLOOR, AND ONE BACKING REINFORCEMENT 9” ABOVE THE RIM OF THE BATHTUB. EACH BACKING REINFORCEMENT SHALL BE 24” LONG MINIMUM AND SHALL BE 24” MAXIMUM FROM THE HEAD END WALL AND 12” MAXIMUM FROM THE FOOT END WALL. FOOT END WALL: ONE BACKING REINFORCEMENT 24” LONG MINIMUM ON THE FOOT END WALL AT THE FRONT EDGE OF THE BATHTUB. HEAD END WALL: ONE BACKING REINFORCEMENT 12” LONG MINIMUM ON THE HEAD END WALL AT THE FRONT EDGE OF THE BATHTUB. SHOWER COMPARTMENTS SHALL HAVE BACKING ON A MINIMUM OF TWO WALLS NOT TO INCLUDE CONTROL VALVE WALL MOUNTED AT 33”-36” ABOVE SHOWER FLOOR. ALL WALL REINFORCEMENT SHALL BE CAPABLE OF RESISTING SHEAR AND BENDING FORCES OF A MINIMUM OF 250 POUNDS. |
||
| 07/06/2026 | Residential Zoning | NOT REQUIRED | |||
| 07/14/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/14/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-RES-0626-03550 Project: Residential Addition/Alteration Location: 1927 E PONDEROSA PL Review Date: 7/14/2026 Reviewer: Joe Macaulay – Civil Engineer - Residential Engineering Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files. Residential Engineering Review Comments: 1. Site engineering will be unable to approve permit TC-RES-0626-03550 until the associated FPU permit (TE-FPU-0626-00272) is approved. If you have any questions or concerns, please contact Joe Macaulay at Joe.Macaulay@tucsonaz.gov |
||
| 07/01/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |