Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0626-03507
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/02/2026 | Residential Engineering | NOT REQUIRED | |||
| 07/10/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/10/2026 | Residential Building - Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-RES-0626-03507 ADDRESS/PARCEL: (2704 E ELM ST TUCSON, AZ 85716) Submit your revised reports along with a response letter which states how all Building Review Section comments were addressed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. Should you have any questions about these comments, I can be reached at ian.gillaspie@tucsonaz.gov. COMMENTS: 1. A less than 3’ fire separation distance requires a 1hr fire rated wall assembly per Section R302.1 IRC CoT adopted. This would apply to the South wall and potentially the West wall. Please clarify the setback distance of the West wall to the property line. 2. Please show conformance with NEC 2017 NFPA 70 Chapter 110.27 for the EV Charger. 3. Please correct and resubmit. |
||
| 07/08/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0626-03507 – Residential Building 2704 E Elm St, Tucson, AZ 85716 Residential Addition/Alteration (1st Review) TRANSMITTAL DATE: July 8th, 2026 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .8, .9, & .12. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) The minimum perimeter yard setback in the R-2 zone is 5’. The proposed detached garage has an indicated setback of ½” from the western property line, and a proposed setback of 1’-10” from the southern property line. Signed waiver statements from the property owners of 1638 N Sawtelle Ave and 1622-26 N Sawtelle Ave must be added to the site plan to approve the detached garage within the required setback. The following statement can be used. My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ Ejemplo de renuncia de retroceso de un propietario adyacente para chalets estructuras accesorias. Declaración de exención del propietario adyacente debe agregarse al plan de sitio. Puede utilizar la siguiente instrucción. Mi hombre es ________________ y yo soy el dueño de la propiedad ubicada en la _____________________. He revisado el plan y no tengo ninguna objeción a que estructura se encuentra o construye ____________ desde la línea de propiedad, como se muestra en el plan. Firma: ________________________________ Fecha: ________________________________ 2. (Comment) If a signed neighbor statement cannot be acquired from the property owner adjacent to the garage at 1622-26 N Sawtelle Ave, A Design Development Option (DDO) is required to reduce the required perimeter yard setback to 1’-10” from the southern property line. Please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For additional questions regarding DDOs, contact Mark Castro at mark.castro@tucsonaz.gov for more information. 3. (Comment) If a signed neighbor statement cannot be acquired from the property owner adjacent to the garage at 1638 N Sawtelle Ave, a Board of Adjustment Variance would be necessary to reduce the required setback to less than one foot from the western property line. More information about the B/A can be found at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Public-Meetings-Boards-Committees-Commissions/Board-of-Adjustment. If you are interested in exploring this option, please, contact Mark Castro at mark.castro@tucsonaz.gov for more information. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 06/30/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |