| 06/25/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/25/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov Please resubmit addressing the following comments: 1) Include pipe size, type (Black Iron, Poly) and length to appliances. With the current pipe size, the furthest length the 1" pipe can supply is 60' per G2413.2, G2413.4 Please verify the lengths from house connection will not exceed 9' or upsize pipe based on the furthest appliance from gas meter using G2413.2 Note: Underground piping systems shall be installed a minimum depth of 12 inches below grade G2415.12 (404.12) |
||
| 06/25/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |