Permit Number: TC-RES-0626-03359
Parcel: 140130660

Address:
2001 E PINE ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.2

Permit Number - TC-RES-0626-03359
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/25/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/25/2026 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov

Please resubmit addressing the following comments:

1) Include pipe size, type (Black Iron, Poly) and length to appliances. With the current pipe size, the furthest length the 1" pipe can supply is 60' per G2413.2, G2413.4 Please verify the lengths from house connection will not exceed 9' or upsize pipe based on the furthest appliance from gas meter using G2413.2

Note: Underground piping systems shall be installed a minimum depth of 12 inches below grade G2415.12 (404.12)
06/25/2026 PDSD Application Completeness Express REVIEW COMPLETED