Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0626-03217
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/18/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/18/2026 | Light Residential Building Review (OIP) - Standard | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov Please resubmit addressing the following comments: 1) The sum of supply sources (60A) exceeds the maximum allowable capacity (40A) for this 200A busbar rating, an additional derate is not permitted by code to adhere to 705.12. If a PMS system is used, please demonstrate the busbar setting and/or any additional information demonstrating adherence to NEC 705 and 750. |
||
| 06/16/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |