Permit Review Detail
Review Status: In Review
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-0626-03176
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/24/2026 | Light Residential Building Review (OIP) - Standard | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov Please resubmit addressing the following comments: 1) The 3/4" main branch pipe from the meter is undersized for the given length and appliance demand. Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) (Polyethylene Plastic Pipe), or Manufacturer’s sizing requirements. |
||
| 06/24/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |