Permit Number: TC-RES-0626-03104
Parcel: 130112880

Address:
2044 S MARCH PL

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0626-03104
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/18/2026 Residential Building - Standard APPROVED Submit Truss package as deferred submittal
06/18/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/12/2026 Residential Engineering REQUIRES RESUBMIT Permit Activity Number: TC-RES-0626-03104 (1st Review)
Project: Additional Dwelling Unit (ADU)
Location: 2044 S MARCH PL
Review Date: 6/12/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering
Reviewer Contact: Marco.contreras@tucsonaz.gov
Related cases:

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed to ensure final approval from Site Engineering.
To help speed up your resubmittal and facilitate shorter review timelines, please include a response letter along with your updated plans and any supporting calculations. In your response letter, address each comment individually and explain what changes were made and where they can be found in the plans. Please do not mark or highlight changes in the drawings at this stage — revision markups are only used after a permit has been issued. Submit your response letter and updated plan set as two separate files.
Site Engineering Review Comments:
1. The City of Tucson Inclusive Home Design Ordinance requires all new dwellings — including ADUs, single-family residences, and duplexes — to provide an accessible route connecting the public street, sidewalk, or driveway to an accessible entrance of the home. This pathway must be shown, dimensioned, and labeled on the plans. What this means in plain terms: There needs to be a clearly defined, walkable path from where a person arrives (the street, sidewalk, or driveway) all the way to a usable door of the home — one that someone using a wheelchair or mobility aid could navigate without barriers. An exterior accessible route that shall conform to 2017 ICC A117.1 Sections 402 and 403 and City of Tucson Inclusive Home Design Ordinance.
Reference: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf
Action Items — Show the following on your plans:
• Draw and label the path as "Accessible Route"
• Provide a minimum clear width of 4 feet with a width call-out on the plans
• Note the proposed running slope (must not exceed 5% / 1:20) and cross slope (must not exceed 2% / 1:50)
• Identify the accessible entrance the route leads to

Acceptable Accessible Route compositions include:
• Portland cement concrete (PCC)
• Broom Finished concrete
• Brick or unit pavers (Only if set on a stable cement base with no gaps exceeding ½”)
• Concrete pavers on concrete base (Same joint and evenness requirements as brick)
• Flagstone: must be mortared – loose set does not qualify
• Any surfaces equivalent in smoothness, hardness, and durability
NOTICE: Decomposed granite (DG) is not permitted for required accessible routes, even if compacted
06/16/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Claire Leighou, Planner

PROJECT: TC-RES-0626-03104

2044 S MARCH PL

Two Bedroom Addition (1st Review)

TRANSMITTAL DATE: 6/16/26

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9.

Comment 1: Based on aerial imagery of the site from 2024, there is a shed along the north edge of the property. Zoning was unable to find the permit associated with this structure. If it was permitted at the time of build, please include in the supporting documents. If not, it may be included in this permit. Please draw, label, and dimension this structure on the site plan. Include the height, square footage, and the setback distance to the adjacent property line. Include this in the lot coverage calculations. Please note that 5’ is the minimum setback distance for side yards; if the structure is within this setback, a neighbor waiver may be used to allow the reduced setback.

If this structure has since been removed, please include a note explaining such on the site plan.

Comment 2: The site plan (page S1) shows the proposed addition labeled as an ADU and includes what appears to be a full kitchen with a stove and refrigerator. Please correct this to ensure all labels are consistent and show this proposed addition as a sleep quarters only.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you!
06/11/2026 PDSD Application Completeness Express REVIEW COMPLETED