Permit Number: TC-RES-0626-03074
Parcel: 123111120

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0626-03074
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/12/2026 Residential Engineering NOT REQUIRED
06/23/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/23/2026 Design Review - Standard REQUIRES RESUBMIT Design review may be required. Please resubmit plans clarifying the scope of work, and include existing and proposed elevation drawings as seen from the street.
06/23/2026 Residential Building - Standard REQUIRES RESUBMIT 1. Show fire separation or fire rating on site plan. The structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by protecting the structure placed within 3 feet of the property line in compliance with IBC Table 721.1(2).
2. Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5.
3. Show an individual accessible water supply shut off for the proposed dwelling unit, P2903.9.1.
4. Update plans to show and reflect 2024 I codes and 2023 NEC.
06/15/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner
PROJECT: TC-RES-0626-03074
1321 E Lester St., Tucson, AZ 85719
Remodel Sleeping Quarters (1st Review)

TRANSMITTAL DATE: 06/15/2026

This site is located within the NR-1 Zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. The project lies within the Jefferson Park Historic District in a Neighborhood Preservation Zone overlay. A Preservation Zone Design Review is required and must be approved prior to Residential Zoning approval since. Front-facing garages in the Jefferson Park Neighborhood are to be avoided per the Neighborhood Design Manual. More information, including a submittal checklist and pdf copies of the design manuals can be found here:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Special-Districts .

A pre-application conference is required prior to Design Review submittal and can be requested through the Permitting Portal by searching for "Pre-application conference," and selecting the Special Districts subtype.

Once the Design Review has been approved, please upload the decision letter with the site plan and other construction packet materials for TC-RES-0626-03074 and include a response letter addressing all staff comments for this review cycle.

2. A “New Porch” is shown on the site plan (Sheet G101) between the garage and the SFR. No building permits are found for this structure. Please clarify that this porch proposal will be permitted separately.

3. Also included on Sheet G101 are an owner suite patio plans. Please remove these or provide a note that this project will be permitted separately.

4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
06/10/2026 PDSD Application Completeness Express REVIEW COMPLETED