Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0626-02979
Parcel: 11507223A

Address:
241 W LEE ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0626-02979
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/24/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/12/2026 Residential Building - Standard REQUIRES RESUBMIT ACTIVITY NO. TC-RES-0626-02979
ADDRESS/PARCEL: (241 W LEE ST TUCSON, AZ 85705)
Submit your revised reports along with a response letter which states how all Building Review Section comments were addressed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. Should you have any questions about these comments, I can be reached at ian.gillaspie@tucsonaz.gov.
COMMENTS:
1. Please show compliance with IRC R403.1 through R403.1(1) for exterior wall footings. Also provide details showing compliance with R404.1.6.
2. Show compliance with IRC R302.3 through R302.3.3.2 fire rated construction between two dwellings.
3. Please show compliance with IRC E3606.5 through E3606.5.3. Whole home surge protection device required.
4. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc.
5. Please correct and resubmit.
06/24/2026 Residential Engineering REQUIRES RESUBMIT Permit Activity Number: TC-RES-0626-02979
Project: Residential Alteration/Addition
Location: 241 W LEE ST
Review Date: 6/24/2026
Reviewer: Joe Macaulay – Civil Engineer - Residential Engineering

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files.

Residential Engineering Review Comments:
1. A floodplain use (FPU) permit has been created for this commercial Addition/Alteration permit, TE-FPU-0626-00262. The lot exists in FEMA regulated Zone “AE” associated with the Bronx Wash, and a floodplain use (FPU) permit with cost estimate is needed for all building permits.
2. Site engineering will be unable to approve permit TC-RES-0626-02979 until the associated FPU permit (TE-FPU-0626-00262) is approved.
3. Per the City of Tucson Inclusive Home Design Ordinance https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”.
a. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance on the site plan. Ensure the route meets accessibility standards as articulated in 2017 ICC A117.1 Sections 402-403, including the minimum 4ft-width, slope and composition materials.
b. Please label the accessible entry on the site plan.

If you have any questions or concerns, please contact Joe Macaulay at Joe.Macaulay@tucsonaz.gov
06/16/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner

PROJECT: TC-RES-0626-02979
241 W Lee St., Tucson, AZ 85705
Carport Conversion to ADU (1st Review)

TRANSMITTAL DATE: 06/16/2026

This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Revise the site plan to demonstrate total lot coverage. This includes the ground floor square footage of all enclosed and vehicle use areas divided by the lot size. The resulting number will be a percentage.

2. Provide a landscape plan. Since January 1, 2026, via Ordinance No. 12219 (an amendment to the Unified Development Code), landscaping is required for all new single-family residential, middle housing development, and accessory dwelling units. A landscape plan is to be applied directly to the site plan and the instructions were designed to avoid hiring a landscape architect. Here is the instruction link: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code Essentially, one tree will be required in the front yard (per 1,000 sf of new development, which the ADU is), and then the front width of the lot minus the driveway multiplied by 5 to arrive at the ground cover requirements. Add which plants will be used and the preferred method of watering to the site plan. Trees need to be planted 5 feet from the sidewalk and 10 feet away from any structure. Additional requirements are provided in the link.

3. Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf ), all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications, including slope and composition materials. The accessible route should be a minimum of 4’ in width.

4. Modify the parking spots and vehicle use area shown on the site plan. Per UDC 4.9.7.B.12: “Parking for middle housing is required per UDC Table 7.4.4-1. Required parking may be met with on-street parking or waived if the site is within a quarter-mile walking distance of an “All Ages and Abilities Bikeway” as defined by the Department of Transportation and Mobility or a public transit route. Parking provided is exempt from Section 7.6.4, Landscape Standards. Front yards are permitted one driveway no more than 20 feet in width and up to 400 square feet of additional vehicular use area.” The site is eligible for a parking waiver because the property is within ¼ mile of both a public transit stop and an approved bicycle path. If interested in applying for a parking waiver, add “Middle Housing” to the site plan and state that the property is within Public Transit Line Nos. 10, 16 & 19. Here is the link to the parking waiver map: https://middle-housing-cotgis.hub.arcgis.com/pages/Parking-Waiver-Eligibility

5. Please label the height for the elevations.

6. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
06/08/2026 PDSD Application Completeness Express REVIEW COMPLETED