Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.3
Permit Number - TC-RES-0626-02942
Review Name: RESIDENTIAL ADD/ALT v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/17/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/17/2026 | Residential Building - Standard | REQUIRES RESUBMIT | Please review the comments below and resubmit. 1. Please update ALL code references to reflect the 2024 IRC. 2. Please provide an electrical panel schedule 3. R506.3.3 Vapor retarder: a minimum 6 mil polyethylene vapor retarder with joints lapped not less than 6 inches is required between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist. |
||
| 11/13/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |