Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-0626-02903
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2026 | Residential Building - Standard | APPROVED | |||
| 06/29/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/29/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0626-02903 – Residential Building 6026 E 33rd St, Tucson, AZ 85711 Residential Addition/Alteration (2nd Review) TRANSMITTAL DATE: June 29th, 2026 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9 & .12 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) The subdivision plat map shows a 15’ utility easement between 6026 E 33rd St and 6018 E 33rd St. This easement would extend 7.5’ from the western property line. Please show the easement on the site plan. The subdivision plat map can be found here: https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=13039 2. (Comment) The proposed carport indicates a setback of 6’ from the property line. Either adjust the position of the carport to be outside of the easement or provide proof that the easement is no longer in effect. 3. (Comment) Provide the zoning classification of the property, which is R-1. 4. (Comment) Indicate the legal description of the property, which is “GOLF LINKS LOT 13” 5. (Comment) Show the total square footage of the property, which is 8,190sqft. 6. (Comment) Show the total square footage of all enclosed structures, not including porches. 7. (Comment) Show, dimension and provide the square footage of all vehicular-use areas. 8. (Comment) Provide a lot coverage calculation, which is the percent of the site occupied by enclosed buildings and vehicular-use areas. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 06/25/2026 | Addressing Validation | REVIEW COMPLETED | |||
| 06/25/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |