Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0626-02878
Parcel: 121112250

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0626-02878
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/05/2026 Residential Engineering NOT REQUIRED
06/04/2026 Residential Zoning NOT REQUIRED
06/09/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/09/2026 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0626-02878
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code and 2018 International Energy Conservation Code. The 2024 International Energy Conservation Code takes effect July 1st. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 IRC code compliance.

Place the current reference code on sheet T1.1.

Provide an Arizona engineer’s calculation, design, and seal for a performance design when minimum sizes are not prescriptive code compliant with the IRC, R301.1.

Provide a separate response letter addressing each comment with location of change on the plans.

PLANS:

1. Buildings with a structural beam exceeding 20 feet require a registered engineer design, ARS 32-144.A.4. Place an engineer seal on the Framing Plan.

MECHANICAL PLANS:

1. Show the size of interior unit (2/M2), M1401.3, M1601.1.
2. Show a dryer vent size and location for venting to exterior, M1501.

ELECTRICAL PLANS:

1. Note all smoke alarms in the building including bedroom #1, R310.
2. Show a surge-protective device (SPD) for the new service panel, E3606.5.
3. Show the washer/dryer circuit size for serving the load, E3702.11.
4. Provide GFCI protection for the washer/dryer receptacle outlet, E3902.12.

If you have any questions, please contact:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Building Safety
06/04/2026 PDSD Application Completeness Express REVIEW COMPLETED