Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0625-03273
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/25/2025 | Fire New Construction - Standard | NOT REQUIRED | |||
| 07/24/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 07/29/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/21/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0625-03273 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. PLUMBING PLANS: 1. Show adopted code references, R106.1.1. Remove the UPC from miscellaneous note #5. 2. Show the water heater rating if proposed as a new unit, P2801.1. MECHANICAL PLANS: 1. Show the HVAC system size accordance with M1401.3, M1601.1. 2. Provide demand calculations in accordance with Manual J standards for the proposed building type and size, M1401.3, M1601.1. ELECTRICAL PLANS: 1. Update the Riser Diagram showing a main panel sized for the total load demand, NEC 225.30 and E3403. 2. Provide a main panel schedule showing the sub panel entries for sub panel feeder wire and breaker sizes, E3404.13 & E3706.2 3. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2. 4. Show the Bathroom receptacle with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. 5. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Show compliance with the energy code requirements with wall and ceiling details referenced at note #4, N1102.1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied to the roof sheathing as part of the R-38 total, R806.5. Also, clarify the window and door ratings. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 07/25/2025 | Site Landscape - Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: STEEL BUILDING FOR GYM AND ENTERTAINMENT ACTIVITY NO: TC-RES-0625-03273 ADDRESS: 2050 S MELPOMENE WY ZONING: SR SUBURBAN RANCH, ENVIRONMENTAL RESOURCE ZONE – (ERZ), HILLSIDE DEVELOPMENT ZONE – (HDZ) This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape and NPPO Section review comments have been addressed. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. HILLSIDE DEVELOPMENT ZONE (HDZ) SEE UDC 5.2, ADD THE FOLLOWING NOTES TO THE SITE PLAN: Vegetation Retention and Revegetation a. Vegetation Retention (1) Existing viable and transplantable trees with four inch or greater trunk diameter and cacti shall be preserved in their original locations, except for building sites and access and utilities serving building sites. (2) When retention of the above trees and cacti in their original locations is not possible due to building site location, the trees and cacti shall be salvaged and replanted in areas requiring revegetation, whenever possible. b. Revegetation All cut or fill slopes that are no steeper than three horizontal to one vertical and all utility trenches or septic leaching fields that are not located in parking or driveway areas shall be revegetated in compliance with the following standards: (1) All plants used in revegetation shall be the same as the native vegetation on the site prior to grading or clearing or any adjacent site; and, (2) Revegetation shall be accomplished with the following minimum standards for plants: (a) Desert trees, a minimum of 15-gallon size with a minimum trunk diameter of two inches measured at the soil level, or large specimen cactus shall be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading; and, (b) Seeds for trees, desert shrubs, and grasses shall be planted with a density adequate to control erosion and may use one of the following methods of planting: Raked into the soil with appropriate mulch materials; hydroseeding; anchored mulches; or established on jute, rolled straw, or similar material. Another method may be approved by PDSD. (3) A temporary watering system shall be installed until the revegetation materials are established. 3. Slope Stabilization All slopes steeper than a ratio of three horizontal to one vertical, with the exception of retaining walls, shall be stabilized with properly engineered stone riprapping or sculptured rock as follows: a. Stone riprapping shall be hand-placed on the slope; b. The stabilizing material used shall blend with the natural appearance of the site or lot and the surrounding terrain; and, c. Vegetation retention and revegetation should be used in conjunction with riprapping. Thank you. Chad Keller, RLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
||
| 07/29/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0625-03273 2050 S MELPOMENE WY. – SR Detached Steel Building for Gym and Entertainment (1st Review) TRANSMITTAL DATE: July 29, 2025 Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments. This site is located in the SR zone (UDC 4.7.4). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-1). 1. Per UDC Article 6.6.3.D accessory structures, except for accessory dwelling units, shall not exceed 12 feet in height, unless attached to a principal structure. If attached to the principal structure, maximum height permitted shall be the same as for the principal structure. To be considered attached to the main dwelling a 5’-0” wide roofed structure would be required between the Gym and the main dwelling. This structure is required to support a live load of 20 lbs. For this permit to be approved as shown on the plan a Board of Adjustment for Variance will need to be submitted and approved. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov. 2. Remove all setback lines shown on the plan as they are not correct. Review UDC Article 6.4.5.C.1.a & .b for the required street perimeter yard setbacks and UDC Table 6.3-1.A for the south & west perimeter yard setback requirements. 3. Remove the reference to lot coverage from the plan as lot coverage is not applicable in the SR zone for a residential use and the lot coverage calculation is not correct. 4. Per UDC Table 6.3-1.A only one (1) dwelling unit is allowed on a SR Zoned property. Based on what appears to be a full-sized refrigerator shown on the plan, the proposed building constitutes a second dwelling unit. Either, 1) show the refrigerator as an undercounter refrigerator or apply for a Variance to allow the full-size refrigerator. 5. This site is located within the Hillside Development Zone (HPZ) and the Environmental Resource Zone (ERZ) a grading plan is required. A grading plan meeting the requirements of Administrative Manul (AM) 2-06 and Technical Standards Manual (TSM) Section 2 shall be submitted for review. This grading plan is a separate review from the required building plan. Until the grading plan is submitted and approved Zoning cannot approve this permit. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 07/01/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |