Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0625-03196
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/24/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/24/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | Permit Review TC-RES-0625-03196 (6773 E DAVID DR TUCSON, AZ 85730) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide an updated Plan to each of the notated items indicating action taken. For questions: Building_Official@tucsonaz.gov 1. Note and specify piping materials (Black Iron, Gas line PEX, etc.), G2412.9. 2. Missing pipe size and pipe length. Size the pipe based on the length from the meter to the farthest attached appliance and max total demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) Polyethylene Plastic Pipe. Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. 3. You're gas template/drawing is missing typical appliance input (BTU'S) and total demand. |
||
| 06/24/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |