Review Date Reviewer's Name Type of Review Description Status Comments
06/24/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/24/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT Permit Review TC-RES-0625-03196 (6773 E DAVID DR TUCSON, AZ 85730)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide an updated Plan to each of the notated items indicating action taken. For questions: Building_Official@tucsonaz.gov

1. Note and specify piping materials (Black Iron, Gas line PEX, etc.), G2412.9.

2. Missing pipe size and pipe length. Size the pipe based on the length from the meter to the farthest attached appliance and max total demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) Polyethylene Plastic Pipe. Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1.

3. You're gas template/drawing is missing typical appliance input (BTU'S) and total demand.
06/24/2025 PDSD Application Completeness Express REVIEW COMPLETED