Permit Number: TC-RES-0625-03185
Parcel: 133353090

Address:
9022 E SIERRA ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR REVISION v.1

Permit Number - TC-RES-0625-03185
Review Name: RESIDENTIAL SOLAR REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/03/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/31/2025 Light Residential Building Review (OIP) - Standard REQUIRES RESUBMIT Please resubmit addressing the following comments:
1) Please submit unmarked plans for revisions, ensure all lettering and notes do not overlap (See below the solar meter)
2) All equipment must be grounded, please include any manufacturer spec sheets that provide grounding information for the ESS. NEC 625.18 – 625.21, 480.30
3) Provide ampacity calculations in accordance with 310.15(B) (apply 125% for continuous loads per 210.19(A)(1)), include ambient temperature and adjustment factors for conductor count, and show final conductor, OCPD, and voltage-drop compliance.
4) Conduit (1-1/4") supplying the 200A load is undersized. Verify compliance with NEC 2017 Chapter 9, Table 1, and Tables 4–8, ensuring conductor cross-sectional area does not exceed the allowable fill percentage based on the number of conductors in the raceway.
5) Please provide spec sheets for all installed equipment upon resubmission, including Solar panels, optimizers, roof racking equipment, Disconnects, Meters, inverter, battery, and ATS.
6) Please clarify the Wattage of the solar panels installed, 440W were proposed in a previous submission and this page names 460W. Include spec sheets for the modules to confirm.
7) Please clarify whether the Automatic Transfer Switch (ATS) will operate automatically or manually to transfer solar power, in accordance with NEC 2017 Article 702.6. Ensure the device is listed and rated for the intended standby or optional power function.
For any questions, please contact: PDSD-Residential@tucsonaz,gov
11/03/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner

PROJECT: TC-RES-0625-03185
9022 E Sierra St., Tucson, AZ 85710
Residential Solar. (1st Review)

TRANSMITTAL DATE: 11/03/2025

This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Sheet TI shows an existing carport which appears to have been constructed in or around 2015. Please provide the dimension of the carport to the east property line.

2. Zoning does not see where this carport was permitted. The side perimeter setback requirements for the R-1 zone is 6’ or 2/3 the height of an exterior wall, whichever is greater. Please either produce evidence that the carport was permitted or obtain permission from the neighbor (Neighbor Waiver) to the east. Here is an example of a Neighbor Waiver:

My Name is __________________ and I am the property owner of the property located at 9032 E Sierra StI have reviewed the site plan and have no objection to the structure being located or constructed _ft. from the property line as shown on the site plan.

If a Neighbor Waiver not able to be obtained, please apply for a Design Development Option (DDO). To apply for a DDO, please access www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/boards-committees-commissions/drb/012425/ddo-24-81-application-packet.pdf Submit a DDO application under the Zoning Modification sub-record that you will create - for instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov Once approval of the DDO is obtained and the appeal period over, then please resubmit for zoning review with the approval as part of the resubmittal package.

3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
10/10/2025 PDSD Application Completeness Express REVIEW COMPLETED