Review Date Reviewer's Name Type of Review Description Status Comments
06/18/2025 Light Residential Building Review (OIP) Express APPROVED REPAIR RISER AND 200AMP ELECTRICAL SERVICE PANEL.

Please note: Conductors shall have a vertical clearance of not less than 8 feet (2438 mm) above the roof surface. The vertical clearance above the roof level shall be maintained for a distance of not less than 3 feet (914 mm) in all directions from the edge of the roof. See Figure E3604.2.1. [230.24(A)]
06/18/2025 Site Engineering Express NOT REQUIRED
06/18/2025 Bldg Permits - Post Review Express REVIEW COMPLETED