Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0625-03072
Parcel: 126062950

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0625-03072
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/17/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/17/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT PDSD Residential Review Section

PROJECT: TC-RES-0625-03072
200 amp all in one change out, overhead-(1st Review)
(615 N COLUMBUS BL)

TRANSMITTAL DATE: June 17th, 2025

Comments:
1.Provide an aerial view with panel location. The overhead service conductor over the structure requires an 8’ clearance above the roof, E3604.2.1. The 8’ clearance is required to be maintained for a distance of 3’ from the edge of the roof.
Questions email building_official@tucsonaz.gov
06/17/2025 PDSD Application Completeness Express REVIEW COMPLETED