Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0625-03066
Parcel: 117190540

Address:
438 S OTERO AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0625-03066
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/17/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/17/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT PDSD Residential Review Section

PROJECT: TC-RES-0625-03072
Run 50 feet of 1" PE pipe from meter to house. Run 1" black to first tee and run 3/4" black to stove, furnace and water heater.-(1st Review)
(438 S OTERO AV)

TRANSMITTAL DATE: June 17th, 2025

Comments: 1. The ¾” pipe is undersized for the given length and total appliance demand(205,000 BTU). Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) 2. Minimum burial depth, 18” for PE pipe, G2415.12.
3.Yellow tracer wire required for PE pipe, G2415.17.3.

Questions email building_official@tucsonaz.gov
06/17/2025 PDSD Application Completeness Express REVIEW COMPLETED