Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0625-02960
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/03/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/03/2025 | Light Residential Building Review (OIP) - Standard | REQUIRES RESUBMIT | Permit Review TC-RES-0625-02960 (1912 S JEFFERSON AV TUCSON, AZ 85711). Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Provide a lag-bolt connection up-lift calculation demonstrating the wind load supporting capability for 115 MPH, or provide an engineer’s calculation, and sealed design, R301.1, R324.4. An IRC PV roof uplift calculator (XLS) is available on Pima County’s website. https://www.pima.gov/1069/Solar-Wind-Systems 2. When applying for a permit to place new equipment on existing code-compliant roofs, an allowance shall be provided for equipment weighing a maximum of 4 psf and load per attachment point of 45lbs or less. https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Development%20Services/Building/Equipment%20on%20roofs%20.pdf Provide calculations showing total roof equipment weight is a maximum per attachment point of 45lbs or less and distributed weight is 4psf or less. R324.4.1.1 Building_official@tucsonaz.gov |
||
| 06/23/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | Permit: TC-RES-0625-02960 Location: 1912 S JEFFERSON AV Review Date: 6/23/2025 Site Engineering Comments: 1. This project lies within a recognized floodplain and requires a Floodplain Use Permit (FUP) along with an elevation certificate. Please start a new FPU at our permit application web page: https://tdc-online.tucsonaz.gov/#/home 2. Site engineering will be unable to approve the associated residential building permit TC-RES-0625-02960 until the associated Floodplain Use Permit (FPU) is reviewed and issued. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 06/10/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |