Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0625-02887
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/02/2025 | Residential Building - Standard | APPROVED | |||
| 06/25/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 07/07/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/07/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Krista Hansen Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0625-02887, R-1 6642 E COOPER ST TUCSON, AZ 85710 Residential Addition (1st Review) TRANSMITTAL DATE: July 7, 2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. 01. COMMENT: Based on aerial photos there are two sheds on southern property line that appear sometime around 2020 and 2012. Zoning was not able to find approved permit documents for these additions. They also appear to not meet setbacks on the south property line, which is 6 feet or 2/3 (H) height of the adjacent wall, whichever is greater (UCD Table 6.3-2.A). On the next submittal, please: a. Show the structures on the site plan. Provide perimeter yard setbacks, height of the structures, and square footage. Add square footage to lot coverage. b. Per UDC Article 6.6.2.D, an accessory structure that is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the site plan and be signed and dated by the adjacent property owner (6641 E KORALEE DR): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ 02. COMMENT: Per UDC Article 6.4.3.C.1.a, roofed areas that are open on at least one side (like porches) are excluded from lot coverage calculation. Remove porches from total lot coverage. 03. COMMENT: Dimension and label the alley on the south side of the property. Per subdivision plat map (MP-09-096), the width of the alley is 20’. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments above, along with a response letter indicating how Site Zoning comments were addressed. Instructions for resubmittal: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For questions regarding Zoning comments, please contact me at: Krista.Hansen@tucsonaz.gov |
||
| 06/05/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |