| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2025 | Residential Building - Standard | APPROVED | |||
| 06/25/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 07/02/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/02/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-0625-02875 1930 E Wyoming St. Tucson, AZ 85706 Enclose Carport into Bedroom (1st Review) TRANSMITTAL DATE: 7/2/2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference. 2. Comment: Please include the surrounding zoning classification on your site plan as noted in the sample site plan. This property is surrounded by R-1 zoning. 3. The zoning provided in your code check (CR-4) is incorrect. This property is located in the R-1 zone. Please update. 4. Comment: Please draw, label, and dimension the ½ Right of Way from the centerline to the base of the wedge curb and from the base of the wedge curb to the property line along E. Wyoming Street. Please refer to paving improvement Plan I-74-002 Pg. 5 if necessary: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-74-002. 5. Comment: Please dimension the rear alley which is 16’. 6. Comment: Per UDC 6.4.3.C.1, “Roofed areas, open on at least one side, which provide shelter to exterior areas such as balconies, entrances, stoops, and terraces, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking are excluded from lot coverage calculations.” Please remove the covered porches from your lot coverage calculations and update the calculations. Also, the vehicular use area needs to be included in the lot coverage calculations. 7. Comment: As this property is located in the R-1 zone, please include a complete floor plan to clearly show all rooms in the house. The plans provided do not show the entire floor plan. UDC Article 4.9.7.B.7 states “For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard.” 8. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 06/04/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |