Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0625-02862
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/04/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | Permit Review TC-RES-0625-02862 (1802 S AVENIDA URSA TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans with the notated items indicating action taken. For additional questions: Building_Official@tucsonaz.gov 1. Non-metallic water line requires blue tracer line. 2. Missing minimum burial depth, 12'', P2603.5. 3. A minimum 1'' service pipe is required when supplying more than 9.5 fixtures 4. Note: PRV required if PSI greater than 80 |
||
| 06/03/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |