Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0625-02850
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/04/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | Permit Review TC-RES-0625-02850 (5851 E CALLE SILVOSA TUCSON, AZ 85711 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide an updated Plan of the notated items indicating action taken. For questions: Building_Official@tucsonaz.gov 1. You're gas template/drawing should show the connection to all appliances and just highlight/call out the segment that's being repaired. 2. Missing minimum burial depth, 18'' for non-metallic pipe G2415.12 3. Yellow tracer wire required for non-metallic pipe underground, G2415.17.3. |
||
| 06/03/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |