06/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/04/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT Permit Review TC-RES-0625-02850 (5851 E CALLE SILVOSA TUCSON, AZ 85711

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide an updated Plan of the notated items indicating action taken. For questions: Building_Official@tucsonaz.gov

1. You're gas template/drawing should show the connection to all appliances and just highlight/call out the segment that's being repaired.

2. Missing minimum burial depth, 18'' for non-metallic pipe G2415.12

3. Yellow tracer wire required for non-metallic pipe underground, G2415.17.3.
06/03/2025 PDSD Application Completeness Express REVIEW COMPLETED