Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0625-02837
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/24/2025 | Residential Building - Standard | APPROVED | |||
| 06/25/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 07/01/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/01/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0625-02837 919 W FRESNO ST. – R-2 Bedroom, Bathroom and Covered Porch (1st Review) TRANSMITTAL DATE: July 1, 2025 COMMENTS: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation. 2. Per UDC Table 6.3-2.A for a Residential Use to a Residential Zone the minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line. As no setback dimension was provided from the proposed patio cover to the east property line Zoning cannot verify perimeter yard setback dimensions. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Per UDC Article 6.4.5.D.1.b a roof overhang may extend up to 2’-0” into the required perimeter yard setbacks. Show the allowed 2’ overhand on the plot plan and provide a dimension from the allowed overhang to the east property line. Based on a wall height of 9’-6” the required perimeter yard setback from the proposed patio cover to the east property is 6’-4”. As it does not appear this setback is met a Design Development Option (DDO) must be submitted and approved to reduce the required setback. 3. Per UDC Table 6.3-2.A for a Residential Use to a Non Residential Zone the minimum setback is the greater of ten (10) feet, or three-quarters (3/4) the height of the structure’s wall facing each interior property line. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Based on a 9’-6” wall height the required perimeter yard setback from the proposed addition to the west property line is 10’-0”, proposed setback is 8’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 06/03/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |