Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0625-02837
Parcel: 112071820

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.3

Permit Number - TC-RES-0625-02837
Review Name: RESIDENTIAL ADD/ALT v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/11/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/11/2025 Site Zoning - Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0625-02837
919 W FRESNO ST. – R-2
Bedroom, Bathroom and Covered Porch (2nd Review)

TRANSMITTAL DATE: August 11, 2025

This comment was not addressed. COMMENTS: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. Until the DDO is approved Zoning cannot approve this permit.

2. Remove the setback lines from the plan as some are not correct.

3. This comment was not addressed correctly. Based on a wall height of 9’-6” the required perimeter yard setback from the proposed patio cover to the east property is 6’-4”, Based on the 7” dimension provided from the roof line the proposed setback is 2’-7”. Per UDC Table 6.3-2.A for a Residential Use to a Residential Zone the minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line. As no setback dimension was provided from the proposed patio cover to the east property line Zoning cannot verify perimeter yard setback dimensions. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Per UDC Article 6.4.5.D.1.b a roof overhang may extend up to 2’-0” into the required perimeter yard setbacks. Show the allowed 2’ overhand on the plot plan and provide a dimension from the allowed overhang to the east property line. Based on a wall height of 9’-6” the required perimeter yard setback from the proposed patio cover to the east property is 6’-4”. As it does not appear this setback is met a Design Development Option (DDO) must be submitted and approved to reduce the required setback.

4. Per UDC Table 6.3-2.A for a Residential Use to a Non Residential Zone the minimum setback is the greater of ten (10) feet, or three-quarters (3/4) the height of the structure’s wall facing each interior property line. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Based on a 9’-6” wall height the required perimeter yard setback from the proposed addition to the west property line is 10’-0”, proposed setback is 6’-11”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
08/06/2025 Zoning Modifications - DDO Standard REQUIRES RESUBMIT The DDO application has been uploaded toTP-MOD-0825-000036. Refer to this sub-record for status and progress of the DDO application. Please allow 6 weeks for this process. If the application is approved, please include with your required comment response letter a copy of the DDO decision letter when you resubmit under your permit TC-RES-0625-02837. If you have questions, please email Mark.Castro@tucsonaz.gov
07/15/2025 PDSD Application Completeness Express REVIEW COMPLETED