Permit Number: TC-RES-0625-02801
Parcel: 133290540

Address:
8401 E SHILOH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0625-02801
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/23/2025 Site Engineering - Standard NOT REQUIRED
07/01/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/23/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0625-02801
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections.

Note the 2018 IRC reference on the plans.

The plans may require additional changes for showing 2018 IRC compliance of construction performed without a permit. Provide plans showing all changes after the last completed permit and proposed alterations.

Provide construction plans with sheet numbering in a single PDF file.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

SITE PLAN:

1. Show the location of the electric service panel, R106.1.1. Identify the utility lines requiring upgrade or replacement.
2. Show the square footage of the enclosed space and carport using exterior dimensions, R106.1.1.

PLANS:

1. Show the functional name of each existing adjacent room, R106.1.1. Existing bedrooms with removed windows require code compliance for egress, R310. Include any alteration of door or window openings between original rooms and proposed rooms for this permit.
2. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)).
3. Provide a Roof Framing Plan with dimensions showing the beams sized for supporting live and dead structural loads (Table R602.7(3)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1.

SECTIONS - DETAILS:

1. Provide a wall section detail with (#4 rebar) reinforced 12” x 12” reinforced foundations for anchoring exterior framed (insulated) walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6.
2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1.
3. Any conditioned space requires a thermal barrier. Clarify the placement of any ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5.

PLUMBING PLANS:

1. Show any alterations.

MECHANICAL PLANS:
07/01/2025 Site Zoning - Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0624-03453
8401 E SHILOH St. – R-1
Convert Existing Carport to Storage & add New Attached Carport (1st Review)

TRANSMITTAL DATE: July 1, 2025

COMMENTS: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example, to include but not limited to:
a. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1” = 20’.
b. Provide the owners name on the plot plan.
c. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements.
d. Provide a dimension from the centerline of Shiloh St. to the face of curb, and from the face of curb to the applicable property line. Per Construction Plan I-65-019, found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-655, sheet 9, the distance from center line of Shiloh the face of curb is 16’ and from face of curb to the south property line is 9’
e. Show all utility lines on the plot plan.
f. Indicate the zoning of this parcel and all adjacent parcels on the plot plan.
g. Provide the legal description “CENTENNIAL PARK LOT 39” on the plot plan.
h. Clearly show the posts supporting the proposed carport and provide perimeter yard setback dimensions to the appliable property lines.
i. Show all property dimensions on the plot plan.

2. Provide full building plans with the next submittal. Requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
06/02/2025 PDSD Application Completeness Express REVIEW COMPLETED