Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0624-03872
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/12/2024 | Residential Building | APPROVED | |||
09/10/2024 | Site Engineering | NOT REQUIRED | |||
09/12/2024 | Site Landscape | NOT REQUIRED | |||
09/12/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/08/2024 | Fire New Construction | PENDING ASSIGNMENT | |||
09/06/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Ramiro Olivarez Planner, Zoning Review Section PROJECT: TC-RES-0624-03872 3249 E CAMINO CAMPESTRE TUCSON, AZ 85716 – RX-1 Zoning (Airport Hazard District) Kitchen relocation and addition (2nd Review) TRANSMITTAL DATE: 09/06/2024 This site is located in the RX-1 zone (UDC 4.7.6). A single-family residence is a permitted use in this zone (Table 4.8-1) subject to Use Specific Standards 4.9.7.B.6, .8, & .9. COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. The following comments were not addressed in full. 1. Comment: Label the Zone (RX-1) and all adjacent zones on the site plane. Or show a zoning detail of this properties zone and all adjacent property zones. (As noted on the sample plot plan below) Aerial views of this property show a detached structure in the rear center of the yard. All structures shall be drawn, labeled, and dimensioned on the plot plan and included in the lot coverage calculation. If this structure is no longer there, please indicate the structure has been removed from the site. See the link below for the information that is required on the plot plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf 2. Comment: The Code & Zoning still does not reflect the correct zone (RX-1) information in full. The perimeter yard setbacks for the RX-1 zone is 20’ and the maximum height is 30’ per UDC 6.3.4 Table 6.3-1 A. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-4908 3. Comment: The West and East property dimensions do not match the dimensions found in the recorded subdivision plat map. They should be 298 feet per recorded plat book 5 page 32) (https://gis.pima.gov/maps/detail.cfm?&parcel=126211100) 4. Comment: Additional comments may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Provide updated site plan in the next submittal. If you have any questions about this transmittal please contact Ramiro Olivarez Ramiro.Olivarez@tucsonaz.gov |
||
08/08/2024 | PDSD Application Completeness | REVIEW COMPLETED |