Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0624-03872
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/10/2024 | Residential Building | APPROVED | |||
07/03/2024 | Fire New Construction | NOT REQUIRED | |||
08/05/2024 | Site Engineering | NOT REQUIRED | |||
08/05/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
07/31/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Ramiro Olivarez Zoning Review Section PROJECT: TC-RES-0624-03872 3249 E CAMINO CAMPESTRE TUCSON, AZ 85716 – RX-1 Zoning (Airport Hazard District) Kitchen relocation and addition (1st Review) TRANSMITTAL DATE: 07/31/2024 This site is located in the RX-1 zone (UDC 4.7.6). A single-family residence is a permitted use in this zone (Table 4.8-1) subject to Use Specific Standards 4.9.7.B.6, .8, & .9. COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Comment: Label the Zone (RX-1) and all adjacent zones on the site plane. The site plan should be designed to include the information as noted on the sample plot plan. All structures shall be drawn, labeled, and dimensioned on the plot plan and included in the lot coverage calculation. See the link below for the information that is required on the plot plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf Verify the scale measurement indicated are correct. (Using the site plan scale (1/30” = 1’0”) measuring the site dimensions and setbacks are off.) 2. Comment: The Code & Zoning information provided is for an R-1 zone. This property is located in an RX-1 zone. Update the Code & Zoning to reflect the correct zone information. Add a note to the cover page, code & zoning section, that this site is in the Airport Hazard District. 3. Comment: The property dimensions do not match the dimensions found in the recorded subdivision plat map (298’ x 153.60’ per recorded plat book 5 page 32) (https://gis.pima.gov/maps/detail.cfm?&parcel=126211100) 4. Comment: Additional comments may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Provide updated site plan in the next submittal. If you have any questions about this transmittal, please contact If you have any questions about this transmittal, please contact Ramiro Olivarez Ramiro.Olivarez@tucsonaz.gov |
||
07/03/2024 | PDSD Application Completeness | REVIEW COMPLETED | |||
07/31/2024 | Site Landscape | REVIEW COMPLETED |