Permit Number: TC-RES-0624-03860
Parcel: 127131080

Address:
450 N SAHUARA AV

Review Status: Requires Resubmit

Review Details: BUILDING DEFERRED SUBMITTAL REVIEW v.2

Permit Number - TC-RES-0624-03860
Review Name: BUILDING DEFERRED SUBMITTAL REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/29/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
11/29/2024 Stair Design (Deferred Submittal) REQUIRES RESUBMIT Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The review will not proceed without the response letter.
COMMENTS:
SECOND REVIEW:
1. Please amend plans to provide construction drawings showing dimensions and connections used for the components. IBC 107.2.1
A. For example, specify each connection and provide symbols to indicate the type of weld to be used at each connection.
B. Provide the dimension of the tread at the connection to the center support column.
2. Please amend plans to show the following information. IRC R311.7.10.1
A. Each tread shall have a depth of not less than 63/4 inches at the walkline.
B. Headroom shall be not less than 6 feet 6 inches (1982 mm).
3. Please amend plans to provide artificial light source located at the top landing of the stairway. R303.8

5. Please resubmit.

Please contact me if you have any questions about these comments.
Mark Masek
Plans Examiner – Building Safety