Permit Number: TC-RES-0624-03720
Parcel: 119043780

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.2

Permit Number - TC-RES-0624-03720
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/26/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/26/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0624-03720 (3525 S LIBERTY AV TUCSON, AZ 85713)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).


1. Provide the type of conductors being used. Show conductors rated for use in wet locations per E3803.10.
2. Provide conduit size/wire type, both direct burial rated.
3. Show weatherproof covers at electrical boxes in damp or wet locations, E3905.11.
4. Note on the plans that all underground electrical shall comply with E3803 for minimum burial depths.