Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0624-03682
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/18/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/18/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | PDSD Residential Review Section PROJECT: TC-RES-0624-03682 Replace leaking original gas line-(1st Review) (243 E Fairground Dr.) TRANSMITTAL DATE: June 18th, 2024 COMMENTS: Plan review for the above referenced structure has been completed. Please submit a gas piping template. 1. Include total developed length( Distance from meter to furthest appliance) 2. Include appliances with Btu for each. 3. Label all gas appliances with gas pipe sizes. Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) (Polyethylene Plastic Pipe). Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/sample_gas_template_0.pdf https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf Any questions please email building_official@tucsonaz.gov |
||
| 06/18/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |