Permit Number: TC-RES-0624-03676
Parcel: 12609049A

Address:
4149 E OXFORD DR

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0624-03676
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/29/2024 Site Zoning APPROVED
06/28/2024 Fire New Construction NOT REQUIRED
08/02/2024 Site Engineering NOT REQUIRED
08/02/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/08/2024 Residential Building REQUIRES RESUBMIT TC-RES-0624-03676
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

Provide a response letter on separate file with the updated construction plan set.

SECTIONS - DETAILS:

1. Provide a complete cross-section detail showing pressure treated interior wall sill plates, R106.1.

MECHANICAL PLANS:

1. Update the whole-house mechanical ventilation description, R303.4; N1103.6 & M1505.4. A one room dwelling less than 1500 SF requires a 30 CFM continuous setting. Identify the continuous rated fan device or fresh air system.

ELECTRICAL PLANS:

1. Provide a Riser Diagram showing a sub panel and feeder size and protection breaker size for proposed casita sub-panel, NEC 225.30, E3403, Table E3704.2(1).

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
06/28/2024 PDSD Application Completeness Express REVIEW COMPLETED