Permit Number: TC-RES-0624-03595
Parcel: 127052140

Address:
4841 E BAKER ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0624-03595
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/13/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/13/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0624-03595 (4841 E BAKER ST TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

1. Aerial views of the property show the overhead service conductors passing over the roof of the multiple structures. The overhead service conductor over the structures requires an 8’ clearance above the roof, E3604.2.1. The 8’ clearance is required to be maintained for a distance of 3’ from the edge of the roof. Show a mast height necessary to achieve this clearance. Check with TEP customer service for service line options. https://www.tep.com/electric-service-requirements

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
06/13/2024 PDSD Application Completeness Express REVIEW COMPLETED