| 08/13/2024 | Site Engineering | NOT REQUIRED | |||
| 08/13/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/16/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0624-03592 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with the updated construction plan set. Field welding requires a special inspection request form for review with the permit plans, R109.2. Provide a certified inspector seal on the form found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Inspections SITE PLAN: 1. Show the location of all utility lines from property line to building(s) along with required alterations, R106.1.1. STRUCTURAL PLANS: 1. Provide a complete plan set showing materials and fastener sizes with 2018 IRC prescriptive compliance or provide an Arizona professional stamped plan set showing performance compliance with wind loading conditions, R301.1. Sealed plans should be available from the manufacturer for pre-designed assemblies. SECTIONS - DETAILS: 1. Provide a structure section showing proposed features including foundation and anchoring size and location, R106.1. ELECTRICAL PLANS: 1. Show any proposed electrical. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 08/12/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0624-03592 1536 N PLAZA DE LIRIOS - RX-2 Detached Metal Shade Structure (1st Review) TRANSMITTAL DATE: August 12, 2024 Provided a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the RX-2 zone (UDC 4.7.7). A single-family residence w/accessory structures is a permitted use in this zone (Table 4.8-1. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, to include but not limited to: a. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1” =20”. b. Provide the owners name on the plot plan. c. Provide the legal description. MIRAFLORES ESTATES LOT 76 & 77, on the plot plan. d. Show all utility lines on the plot plan. e. Indicate the zoning of the parcel and all adjacent parcels on the plot plan. 2. The shape of the parcel and property line dimensions are not correct. Review final plat of Miraflores Estates found at: https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=12090, and provide the correct shape and dimensions. 3. Per UDC Article 6.6.3.E The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure . Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement. Based on the square footages provided the total square footage of the accessory structures exceeds the allowed 50%. A Board of Adjustment for Variance must be submitted and approved. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-2. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code#section-1. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 07/12/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |