Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL FENCE/WALL v.2
Permit Number - TC-RES-0624-03589
Review Name: RESIDENTIAL FENCE/WALL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/17/2024 | Residential Building | NOT REQUIRED | |||
| 06/28/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/28/2024 | Site Engineering | REQUIRES RESUBMIT | This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home NOTE: For fences built in the floodplain, flood venting holes in the fence must be provided at grade. For panel fences, the panels must be elevated 6 inches above the ground or an 8 inch flood vent must be present every 12 inches. For brick walls, an open brick must be present every other brick at grade. Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” Contact Mike Ortiz at Michael.Ortiz@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP. |
||
| 06/20/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0624-03589 2836 N EAST PLAZA DR. – R-1 Metal site fence (1st Review) TRANSMITTAL DATE: June 20, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. 1. As you are proposing a site fence along a public street provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example. 2. The plot plan shall include a dimension from the centerline of Florence Dr. to the face of curb, where pavement meets the concrete curb and from face of curb to the south property line. Based on Paving Plan I-652 found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-652, the distance from centerline of Florence Dr. to the face of curb is 15’-0” and from face of curb is 10’-0” 3. Per UDC Article 6.6.2.I the maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard .) 1. At least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron; 2. Part of, or located on top of, a retaining wall no higher than ten feet measured from design grade and no higher than six feet measured from the top of the retaining portion of the wall; 3. A greater height is required through the rezoning process or the special exception land use process; or, 4. A greater height is required by a specific UDC standard. The proposed 6’-10” exceeds the allowed 6’-0” high fence within a perimeter yard. Either demonstrate that one of the four exceptions listed above is met, or a Design Development Option (DDO) for wall height must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. Once the residential plot plan is provided additional comments maybe forthcoming. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 06/14/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |