Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0624-03586
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/14/2024 | Fire New Construction | NOT REQUIRED | |||
| 07/22/2024 | Site Landscape | NOT REQUIRED | |||
| 07/22/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/25/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0624-03586 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with the updated construction plan set. FLOOR PLAN: Provide a floor plan showing each proposed room with labeled function and dimensions. Show door locations and window sizes with type identified as XO or SH. Include the identification of adjacent rooms with door or window openings leading into the proposed space. An altered bedroom requires code compliance for egress, R310. SECTIONS - DETAILS: 1. Provide a wall section showing proposed features of the new stud wall including a foundation, framing, sills, anchoring, sheathing and insulation, R106.1. The cross-section detail should include a pressure treated sill anchored with ½” x 10” bolts. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5. 2. Provide a header size at the proposed open access between rooms consistent with Table 502.5(1) & R602.7(1). 3. Provide insulation details minimum (R-13 walls and R-30 small additions or otherwise R-38 ceiling) showing code compliant placement of materials and ratings, N1101. 4. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value. ELECTRICAL PLANS: 1. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2. 2. Show a wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 07/17/2024 | Site Engineering | REQUIRES RESUBMIT | 1. See zoning comments Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
| 07/08/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Review Section PROJECT: TC-RES-0624-03586 6158 E Calle Aurora Enclose Garage into Family Room (1st Review) TRANSMITTAL DATE: 7/8/2024 Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. 1. Comment: The site plan should be designed to include the information as noted on the sample site plan. See https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference. 2. Comment: Aerial imagery shows a detached structure located in the Southwest corner of the property. Please draw, label, and dimension this detached structure to include height and setback dimensions. Also, please update your lot coverage to include both sheds on the property. 3. Comment: The existing storage shed on the Northeast portion of the property appears to be located within the utility easement. Approval from utility companies that have interest in the utility easement must be provided, such as TEP, Tucson Water, Southwest Gas, etc. If approval from all utility companies is obtained, then an application for a building permit for the attached shed is required. In addition to the building permit, a Design Development Option (DDO) or a Board of Adjustment Variance will be required due to the proximity of the attached structure to the East property line. The minimum side yard setback is the greater of 6’ or 2/3 the height of the proposed exterior building wall (shed). 4. Comment: Please label adjacent properties zoning classification per the sample site plan. Surrounding properties are all R-1. Zone CR-3 is not a city zoning classification, please remove it. 5. Comment: Please clarify what the converted space will be used for (Bedroom, Game room, etc.). Currently, your plans state the use will be living space. 6. Comment: Label the use of the existing rear covered addition. 7. Comment: Label the front and rear setbacks from the property line. 8. Comment: Label and dimension the vehicular use areas and include this calculation in your lot coverage. 9. Comment: Per the sample site plan, please draw and label the utility locations. 10. Comment: Label and dimension the half right of way to property line. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 06/14/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |