Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0624-03490
Parcel: 11304345A

Review Status: Requires Resubmit

Review Details: RESIDENTIAL POOL v.2

Permit Number - TC-RES-0624-03490
Review Name: RESIDENTIAL POOL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/11/2024 Site Zoning NOT REQUIRED
07/17/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/03/2024 Residential Building REQUIRES RESUBMIT ACTIVITY NO. TC-RES-0624-03490
PROJECT: RESIDENTIAL POOL
ADDRESS/PARCEL: 1125 E FORT LOWELL RD/113-04-345A

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed.

In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken.
Do not cloud the changes made for comment revisions.

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

RESUBMITTAL COMMENTS:
1. *This comment was not adequately addressed* Remove the pool shown at 1115 E Fort Lowell Rd on the site plan. That address is actually not on this parcel. That address is located on Parcel# 11304345B.
2. *This comment was not adequately addressed* Show dimensions between the pool and the property lines, not just the wall, on the site plan.
3. *This comment was not adequately addressed* Show dimensions between water’s edge and structure on the site plan.
4. *This comment was not adequately addressed* Show home run between new 150 Amp panel and main panel on the site plan.
5. Show dimensions between all walls and water’s edge.

More comments may be forth coming once corrections have been made.

Please upload your revised plans to TDC-Online with a revision letter outlining what has been revised on the doc set.

Resubmittals will not be accepted without the revision letter.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov
07/17/2024 Site Engineering REQUIRES RESUBMIT This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.)
Please start a new FUP at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home
NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TIs and solar). Construction of separate builds/new structures does not require a cost estimate to be provided. Construction of new buildings require elevation one foot above the base flood elevation, which may require that the foundation of the building be raised as much as two feet above the existing elevation onsite. Storage buildings with no utilities may be wet floodproofed using flood vents. For all new construction buildings, two elevation certificates must be filled out by a registered land surveyor and submitted to the City, one before the foundation is poured and one after construction is completed.
Instructions:
1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record
2. Locations -> Confirm the location is accurate to the project. Click “Next”
3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next”
4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next”
5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next”
6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next”
7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next”
8. Review and Submit -> Review all information to ensure accuracy. Click “Submit”

Mike Ortiz
michael.ortiz@tucsonaz.gov
07/02/2024 PDSD Application Completeness Express REVIEW COMPLETED